We have proposed SCADA system for Diesel Engine Assembly System based on the MOVICON SCADA connected to the Siemens S7 PLC using Siemens Ethernet communication.The system comprises of central SCADA system, Data Entry Terminals (DET) and View Clients (VC). The central system which reads all data from all stations via the central Siemens PLC will be the Server system.We have proposed to have a HOT redundant system with two servers and one Slave operator Station. The redundant Servers which will automatically switch communication, data storage etc. if one server fails making the system reliable as the DET and View clients are also connected to this network. The Server will have a base MOVICON Runtime PRO system with Editor, Redundancy and required Web Licenses options
enabled.
The DETs proposed are Movicon Runtime Client LITE Stations which will allow operators there to enter data as well as view relevant data in lists or grids as required. These stations will also have capability to read data
from RS232 ports from devices like Bar Code Scanners so that data can be updated directly into the system. They will NOT have any drivers and so will not have capability to talk to complex devices like PLCs but only communicate to single ASCII based device.